12. CCpilot V1000/V1200/V510/V710/V705 and Yukon development board =================================================================== This chapter covers features and behavior unique to the CCpilot V1000/V1200/V510/V710/V705 and the Yukon development board. ============================================================ 12.1 Status indication (LED and buzzer) ============================================================ This section describes the basic default status indication behavior. Note that the status indication behavior can be disabled totally and/or configured by user software through the CCAux API. --------------------------------------- 12.1.1 Startup sequence - main system --------------------------------------- During startup to the main system, the status LED and buzzer indications are as follows: • Flashing yellow at 1 Hz: pre-heating is activated and in effect, start-up is delayed while the device is heated. • Status LED is blinking yellow at 2 Hz and buzzer makes short beep: Device start-up phase begins. • Operating system is then started, and specific service software begins to execute. • Status LED is constant green: Device is operational. -------------------------------------------- 12.1.2 Startup sequence - rescue system -------------------------------------------- During startup to the rescue system, the status LED and buzzer indications are as follows: • Status LED is constant orange and buzzer makes short beep: Device start-up phase begins. • Operating system is then started, and specific service software begins to execute. • Status LED is blinking green at 2 Hz: Device is operational. ------------------------------------ 12.1.3 Suspend ------------------------------------ When the device is in suspend mode, the status LED indications are as follows: • Flashing yellow at 0.2 Hz: system is suspended. • Flashing yellow at 2 Hz: system is resuming from suspend. • Static green: device is operational. ------------------------------------ 12.1.4 Shutdown sequence ------------------------------------ Once ignition signal has been released and shutdown is initiated: • Status LED is constant yellow, and buzzer makes short beep: shutdown sequence has started. Status LED is off: Device is off