12. CCpilot V1000/V1200/V510/V710/V705 and Yukon development board

This chapter covers features and behavior unique to the CCpilot V1000/V1200/V510/V710/V705 and the Yukon development board.

12.1 Status indication (LED and buzzer)

This section describes the basic default status indication behavior. Note that the status indication behavior can be disabled totally and/or configured by user software through the CCAux API.

12.1.1 Startup sequence - main system

During startup to the main system, the status LED and buzzer indications are as follows:

  • Flashing yellow at 1 Hz: pre-heating is activated and in effect, start-up is delayed while the device is heated.

  • Status LED is blinking yellow at 2 Hz and buzzer makes short beep: Device start-up phase begins.

  • Operating system is then started, and specific service software begins to execute.

  • Status LED is constant green: Device is operational.

12.1.2 Startup sequence - rescue system

During startup to the rescue system, the status LED and buzzer indications are as follows:

  • Status LED is constant orange and buzzer makes short beep: Device start-up phase begins.

  • Operating system is then started, and specific service software begins to execute.

  • Status LED is blinking green at 2 Hz: Device is operational.

12.1.3 Suspend

When the device is in suspend mode, the status LED indications are as follows:

  • Flashing yellow at 0.2 Hz: system is suspended.

  • Flashing yellow at 2 Hz: system is resuming from suspend.

  • Static green: device is operational.

12.1.4 Shutdown sequence

Once ignition signal has been released and shutdown is initiated:

  • Status LED is constant yellow, and buzzer makes short beep: shutdown sequence has started.

Status LED is off: Device is off